Showing results: 46 - 60 of 78 items found.
-
-
CP TC12 -
OMICRON electronics
The CP TC12 oil test cell is for determining the relative permittivity, the dissipation factor and the power factor of insulating liquids such as transformer oil.
-
Dielectrotest -
Amperis sl
The Dielectrotest is a fully automatic dielectric oil meter for determining the breakdown voltage of insulating liquid. It is designed for both laboratory and field use for commissioning and maintenance purposes. The test standard is selected via menu.
-
AJIT Electronics Co.
AJIT Transformer Oil Set is completely self contained, compact & portable unit giving smooth variable output voltage from zero to 60/80/100KV for testing the dielectric strength of insulating oil.
-
Neutronics Manufacturing Co.
We offer Manually operated Transformer Oil Testing Kits to check the DI-electric strength of the insulating Oils as per relevant specifications via. IS 6972. It is a useful equipment for transformer / switchgear manufacturing units. Oil frittering agencies, repair shop and electrical maintenance departments.
-
Supreme Instrument Laboratories
Supreme High voltage Oil Testing Apparatus is designed for testing of dielectric strength of transformer Oil or any other insulating liquids. It constitutes a complete equipment and apart of an A.C. supply of 230 / 240 Volts, no other supplementary facilities are required for its operation.
-
NEO TELE-TRONIX PVT. LTD
This testing set is an automated instrument, widely used for measuring electrical characteristics of insulating liquids, transformer oil and other insulating material samples.
-
OTD -
Megger Group Ltd.
The Oil Tan Delta (OTD) is a laboratory instrument, which measures the Tan Delta, Resistivity and Relative Permittivity of insulating liquids. These tests give a wider picture of the overall quality of the insulating oil, and will indicate if there is any contamination. Megger has developed features of the OTD to ensure that productivity levels within laboratories are maximised. The microprocessor controlled inductive heater means that there is uniformity of temperature throughout the cell, in compliance with IEC 60247, and for cooling a fan effectively speeds up the cell cooling time. The instrument has a temperature measuring range of 10 to 110 C, with an accuracy of 1 C. It can be set to preheat before testing takes place. The automated oil drain facility negates the need to move the oil vessel. User safety is paramount and with this in mind, Megger have designed independent and dual redundant high voltage cut-off circuitry. If for any reason the user needs to abort the test, this can be done so by pressing any key, immediately terminating the test and removing the high voltage. The design of the cell components maximise oil fill rate but minimise turbulence in oil flow and eliminate trapping of air. With only 32 cell components, it is easy to assemble and disassemble.
-
DTA 100 C -
BAUR Prüf- und Messtechnik GmbH
Insulating oil testing with the BAUR DTA 100 C. The BAUR DTA 100 C oil tester is designed for continuous operation in the laboratory and is characterised by the combination of extraordinary features. As a high-performance device with a test voltage up to 100 kV, with clear breakdown detection and absolutely reliable measurement results even across several measurement sequences, the BAUR DTA 100 C is the leading testing device for users in the electricity and other industries and in testing institutes.
-
DTL C -
BAUR Prüf- und Messtechnik GmbH
Insulating oil testing with the BAUR DTL C. The established analysis and diagnostic testing of insulating oils with the BAUR DTL C deliver valuable findings in scientific work, research and development. Extensive knowledge on the current state of insulating materials is gaining importance even for the mains network operator. The BAUR DTL C offers the latest and most precise information for efficient oil management in plants in the electricity and other industries.
-
BAUR Prüf- und Messtechnik GmbH
Insulating materials are the elixir of life of electrical equipment. These materials lose their insulating and cooling properties due to impuri ties and ageing. This damages equipment, causes failures and is consequently often accompanied by high costs. Precise and reliable measurement results.
-
DPA 75 C -
BAUR Prüf- und Messtechnik GmbH
Insulating oil testing with the BAUR DPA 75C. The BAUR DPA 75C oil tester developed especially for mobile use in the field is one of its kind in the market due to its functionality and excellent user benefits in comparison to the costs. The BAUR DPA 75C delivers clear and reliable measurement results.
-
DTA IL -
BAUR Prüf- und Messtechnik GmbH
Insulating oil testing with the BAUR DTA IL. The BAUR DTA Inline is a high performance and reliable oil tester for continuous testing of the breakdown strength of insulating oils during production (inline tests). The combination of extremely short switch-off times during breakdowns and the easy oil sample handling facilitate high quality statements and conclusions on the insulating oil quality.
-
Weshine Electric Manufacturing Co., Ltd
Weshine represent the absolute best in the field of transformer oil regeneration and corrosive sulfur removal. Several new features developed inhouse by our research and development department result in the state-of-the-art transformer oil regeneration equipment. Supplemented by our unique corrosive sulfur mitigation process integrated directly into the regeneration process.
-